Grove - Solid State Relay

From Wiki
Jump to: navigation, search

Introduction

Grove – Solid State Relay is a non-contact electronic switch module that has relay features. Based on S208T02, it has a maximum output of 250VAC/4A, with a switching speed less than 10ms. This module is equipped with acrylic base and a 3D-printed protection insulation shield, for user’s safety. The featured LED indicates that the relay is on. It can be widely used in various areas such as computer peripheral interfaces, temperature/speed/light adjustment, servo control, petrochemical, medical instrumentations, financial devices, coal, meters, traffic signals, etc.


Grove Solid State Relay 02.jpg


Features

3D-printed protection insulation shield Compatible with both 3.3V and 5V control level Low switching latency (≤10ms) LED on-state indicator Featured radiator provide better stability Acrylic base and insulation paper increase safety performance Grove compatible Application Ideas

Operations that require low-latency switching, e.g. stage light control Devices that require high stability, e.g. medical devices, traffic signals Situations that require explosion-proof, anticorrosion, moisture-proof, e.g. coal, chemical industries. Specification

Item Min Typical Max Uint Input Voltage 3.0 3.3 5.0 VDC Input Current 16 20 50 mA Output Voltage -- 220 250 VAC Output Current -- -- 4.0 A Operating frequency 45 50 65 Hz Operating temperature -25 25 85 ℃ Turn-on time -- 10 -- ms Turn-off time -- 10 -- ms Dimension 44x44x32 mm Net Weight 25.5 g Interface Function

Ssr interface.jpg

511.6x400px Cautions

 If the output voltage is higher than 36V, you need to ensure the module is in the off state before you operate with the screws.  The heat sink can be in very high temperature, do not touch it during use. Usage

With Arduino The Grove - Solid State Relay has a variety of applications. Here we elaborate on how to use it to control a bulb.

First off, you'll need to connect it to the Arduino like so: 1. Connect the Grove - Solid State Relay to Digital 13 of Grove-Base Shield via a Grove 4 pin wire. 2. Plug Grove-Base Shield onto Arduino and connect Arduino to PC via a USB cable. 3. Connect the bulb to OUTPUT of Grove - Solid State Relay.


Grove - SSR2.jpg


You need upload the below code. Please click here if you do not how to upload. /*

 Grove - Solid State Relay Demo Code
 The ssr will turn on for 5s and then turn off for 5s, and so on.
 http://www.simgin-chip.com
  • /

int ssrControlPin = 13; void setup() {

 // initialize the digital pin as an output.
 pinMode(ssrControlPin, OUTPUT);     

}

void loop() {

 digitalWrite(ssrControlPin, HIGH);      // set the SSR on
 delay(5000);                            // wait for 5 second
 digitalWrite(ssrControlPin, LOW);       // set the SSR off
 delay(5000);                            // wait for 5 second

}

After upload the code, you can see the bulb will light 5s and then turn off for 5s, and so on.

With Raspberry Pi 1.You should have got a raspberry pi and a grovepi or grovepi+. 2.You should have completed configuring the development enviroment, otherwise follow here. 3.Connection Plug the sensor to grovepi socket D4 by using a grove cable. 4.Navigate to the demos' directory:

  cd yourpath/GrovePi/Software/Python/

To see the code

  nano grove_solid_state_relay.py   # "Ctrl+x" to exit #

import time import grovepi

  1. Connect the Grove Solid State Relay to digital port D4
  2. CTR,NC,VCC,GND

relay = 4

grovepi.pinMode(relay,"OUTPUT")

while True:

   try:
       # switch on for 5 seconds
       grovepi.digitalWrite(relay,1)
       print "on"
       time.sleep(5)
       # switch off for 5 seconds
       grovepi.digitalWrite(relay,0)
       print "off"
       time.sleep(5)
   except KeyboardInterrupt:
       grovepi.digitalWrite(relay,0)
       break
   except IOError:
       print "Error"

5.Run the demo.

  sudo python grove_solid_state_relay.py

Test Report

1.Experimental purposes

 1) Thermal performance of Grove – Solid State Relay(S208T02)
 2) Limit load current of Grove – SSR


Grove-ssr-report-image3.jpg

Grove-ssr-report-image2.jpg


 3) Measures to improve the limit load current

2.Experimental Principle By recording SSR chip temperature at different current and different time points, analysis the data and draw conclusions. Figure 1 is screenshot from S208T02 datasheet, we can see that at different heat sink and different temperature, SSR’s current is different.


Figure 1: RMS ON-state Current vs Ambient Temperature

There needs a temperature sensor to get the temperature of the chip. I use DS18B20 whose detection range is -25-125℃ to meet the requirements. Figure 2 shows the experimental equipment and installation plans, the temperature sensor is tied to the right side of the heat sink, to make the temperature that 18b20 detects as close as possible to the heat sink temperature, smear between the sensor and the heat sink thermal plastic. Between the heat sink and SSR coated thermal plastic. Therefore, the temperature of the 18b20 is equal to the temperature of SSR.


Figure 2: Test Temperature

3.Experimental data Table1 time vs temperature 1min 5min 10min 20min stable time 0.5A 31.40 33.75 34.75 35.00 15min 1A 31.8 36.75 39.6 40.56 18min 2A 34.5 46.6 48.88 51.13 20min 3A 35.56 52.81 58.88 60.06 17min 4A 38.00 57.88 63.88 67.00 19min 5A 44.00 66.00 73.12 75.37 19min Note 1: The unit of temperature in the table is ℃ Note 2: When tested room temperature is 28 ℃ 4.Expansion experiment

 In order to prove that improve the level of heat sink will improve the SSR limit operating current, I did an expansion experiment.
 Cuz I hadn’t a larger heat sink on hand, so I installed a fan (which I take for my PC’s CPU) above the SSR. As shown in Figure 3.



Figure 3: Expansion experiment


I just test the stable time of different operating current, as shown in Table 2.

Table2 Stable time of expansion experiment 6.0A 6.5A 7.0A 7.5A Stable time 54.44℃ 57.63℃ 60.06℃ 62.38℃ 5.Expansion experiment From the above experimental results, the following conclusions can be drawn:

1). When current is fixed, with the passage of time, the temperature will stabilize at a certain value. This value is related with the current, the current increases, the stable temperature are greater. At 2A, stable temperature will be more that 50 ℃, So, when the SSR work, you should not touch it. 2). Combined with Figure 1 and our data, I consider that the Grove – SSR can operator 4A load current at max. 3). If load current larger than 5A, such as 7A, you should install a fun on it , or other cooling measures, but it’s not recommended. Support